Platinum Tungsten Alloy

Platinum-Tungsten-Alloy

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Brand Name:DLX   Place of Origin:China Jiangsu    Delivery Time:7-15 Days
Certification:CE,ROHS   Supply Ability:500 tons per month
Payment Terms:L/C,T/T,Western Union,MoneyGram

Classification:

Product Introduction

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Our Pt90/W10 Platinum Tungsten Alloy Wire is a game-changer for medical electrodes, built to deliver top-notch performance in life-saving devices. This isn’t just any wire—it’s a high-purity alloy of 90% platinum and 10% tungsten, crafted for biocompatibility, durability, and precision in applications like pacemakers and neurostimulation leads. With its killer blend of conductivity, strength, and corrosion resistance, it’s the go-to choice for medical engineers who need reliable electrodes that perform flawlessly inside the human body. We’re proud to offer a product that supports cutting-edge healthcare with unmatched quality.

For more details, pls directly contact us.

Let’s dive into what makes our Pt90/W10 wire so special. It’s a high-purity alloy with 90% platinum, delivering excellent electrical conductivity—around 15-20% IACS—for precise signal transmission. The 10% tungsten ramps up strength and durability, hitting a tensile strength of 50-70 ksi, making it tough enough for long-term implantation. With thermal stability up to 1770°C, it handles repeated sterilization processes like autoclaving without breaking a sweat. Its corrosion resistance is a standout, shrugging off bodily fluids like blood and saline, ensuring no adverse reactions. Whether it’s powering a pacemaker or a neurostimulator, our Pt90/W10 wire ensures consistent, reliable performance in critical medical applications.

Platinum Tungsten Wire: Composition, Parameters, and Applications

Category Details
Composition                 90-95% Platinum (Pt), 5-10% Tungsten (W), meeting ASTM B684 standards                
Parameters                
- Density (g/cm³)                 19.8-21.0                
- Tensile Strength (ksi)                 50-70                
- Electrical Conductivity (% IACS)                 15-20                
- Melting Point (°C)                 ~1770                
- Corrosion Resistance                 Excellent; resists oxidation, acids, and arc erosion                
- Wear Resistance                 High due to tungsten addition                
- Temperature Range (°C)                 Up to 1770 (stable in high-temperature environments)                
- Diameter Range                 Customizable, from ultra-fine (e.g., 0.01 mm) to thicker gauges (e.g., 1 mm)                
Applications                
- Automotive                 Spark plugs, ignition system contacts                
- Aerospace                 Relay contacts, avionics wiring                
- Industrial                 Circuit breakers, motor controls, high-frequency switching devices                
- Renewable Energy                 Solar panel connectors, wind turbine control systems                
- Medical Devices                 Precision contacts in diagnostic and surgical equipment                
- Electronics                 High-frequency circuits, IoT devices, telecommunications                

For more details, pls directly contact us.

In medical electrodes, biocompatibility and reliability are everything, and our Pt90/W10 wire nails it. It’s non-toxic, FDA-compliant, and resists corrosion from bodily fluids, making it safe for long-term implants. In lab tests, our wire showed zero degradation after 12,000 sterilization cycles, making it a top pick for pacemaker electrodes and ECG sensor wires. Its high conductivity and low contact resistance ensure accurate signal delivery, which is crucial for devices like neurostimulation leads treating conditions like epilepsy or chronic pain. If you’re searching for Pt90/W10 platinum tungsten alloy wire for medical electrodes, you’re getting a material that boosts device reliability and patient safety, even in the most demanding conditions.

The medical device industry is booming, and our Pt90/W10 wire is right in step with the trends. The global market for implantable medical devices is projected to grow at a 7-9% CAGR through 2030, driven by rising chronic diseases, aging populations, and advances in minimally invasive surgeries. The demand for bioelectronics, like neural implants and smart sensors, is skyrocketing, requiring materials that are both precise and durable. Sustainability is also a big focus—our wire’s longevity reduces the need for replacements, cutting down on medical waste. Emerging fields like wearable health monitors and brain-computer interfaces are increasing the need for high-performance electrode materials. Regions like North America, Europe, and Asia-Pacific are leading the charge, with heavy investments in medtech innovation and regulatory frameworks favoring biocompatible materials.

When it comes to applications, our Pt90/W10 wire is a versatile powerhouse. It’s a staple in pacemaker electrodes, delivering reliable electrical pulses for years. In neurostimulation, it’s used for leads in devices treating Parkinson’s or depression, where its durability ensures consistent therapy delivery. We’ve also supplied it for ECG and EEG sensor wires, where its conductivity supports accurate diagnostics. Beyond implants, it’s used in catheter-based electrodes for minimally invasive procedures and even in emerging bioelectronic devices. We can customize the wire to your exact specs—ultra-fine diameters for micro-electrodes, polished surfaces for biocompatibility, or specific coatings for enhanced performance, all tailored to your device’s needs.

What sets our company apart is our relentless focus on quality and innovation. We produce our Pt90/W10 wire with strict quality controls, from alloy blending to final testing, ensuring every batch meets the highest medical standards. Our advanced drawing and polishing processes deliver ultra-smooth surfaces and precise diameters, reducing signal noise and ensuring patient safety. Compared to standard wires, our Pt90/W10 wire offers superior wear resistance and corrosion protection, thanks to our proprietary manufacturing techniques. We’re also big on sustainability, using recycled platinum to lower our environmental footprint without compromising quality. Our customers love our flexibility—rapid prototyping, custom packaging, and just-in-time delivery keep your projects on track. Our team of materials scientists is always ready to collaborate, whether you’re designing a new implant or optimizing a diagnostic device.

Comparison Parameters Table

Parameter Pt90/W10 Platinum Tungsten Wire Pure Platinum Wire Stainless Steel 316L Wire
Composition 90% Pt, 10% W 100% Pt 16-18% Cr, 10-14% Ni, 2-3% Mo
Density (g/cm³) 19.8 21.45 8.0
Tensile Strength (ksi) 50-70 18-25 70-85
Electrical Conductivity (% IACS) 15-20 16-18 2-3
Corrosion Resistance Excellent; resists bodily fluids, sterilization Excellent; less durable under wear Moderate; prone to pitting
Biocompatibility High; non-toxic, FDA-compliant High; less wear-resistant Moderate; not ideal for implants
Thermal Stability (°C) Up to 1770 Up to 1768 Up to 1400
Cost Factor High due to platinum Very high Low
Typical Applications Pacemaker electrodes, neurostimulation leads Low-current sensors Surgical tools, non-implants

The advantages of our Pt90/W10 wire are hard to beat. Its biocompatibility and corrosion resistance make it a standout for medical electrodes, often outlasting stainless steel by a factor of three in bodily fluid tests. The 10% tungsten gives it a strength edge over pure platinum, ensuring it can handle mechanical stresses without sacrificing conductivity. We’ve helped medical device makers cut failure rates by 20% by switching to our wire for critical applications like pacemaker leads. With trends leaning toward smarter, more compact medical devices, our wire is ready to support the future, from neural implants to advanced diagnostics. It’s a material that’s as reliable as it is forward-thinking.

For more details, pls directly contact us.

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

About Us:

Our 12,000㎡ factory is equipped with complete capabilities for research, production, testing, and packaging. We strictly adhere to ISO 9001 standards in our production processes, with an annual output of 1,200 tons. This ensures that we meet both quantity and quality demands. Furthermore, all products undergo rigorous simulated environment testing including high temperature, high pressure, and corrosion tests before being dispatched, ensuring they meet customer specifications. 

For all our clients, we offer timely and multilingual after-sales support and technical consulting, helping you resolve any issues swiftly and efficiently.

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Client Visits

Building Stronger Partnerships

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

We support all kinds of testing:

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

Pt90/W10 Platinum Tungsten Alloy Wire for Medical Electrodes

FAQs

  • What is the composition of Pt90/W10 platinum tungsten alloy wire?
    It’s an alloy of 90% platinum and 10% tungsten, designed for biocompatible medical electrode applications.

  • What are the key properties of Pt90/W10 wire?
    It offers high electrical conductivity (15-20% IACS), tensile strength (50-70 ksi), corrosion resistance, and biocompatibility.

  • What medical electrode applications use Pt90/W10 wire?
    It’s used in pacemaker electrodes, neurostimulation leads, and ECG sensor wires for reliable performance.

  • How does Pt90/W10 wire perform in the human body?
    It resists corrosion from bodily fluids, is non-toxic, and withstands repeated sterilization without degradation.

  • What industry trends are driving demand for Pt90/W10 wire?
    Growth in implantable devices, minimally invasive surgeries, and bioelectronics is increasing its adoption.

  • Is Pt90/W10 wire suitable for precision medical applications?
    Yes, its fine diameter control and high conductivity ensure accurate signal transmission in sensitive electrodes.

  • How is Pt90/W10 wire customized for medical electrodes?
    It’s drawn to ultra-fine diameters, polished for biocompatibility, or coated to enhance performance in medical devices.

  • What makes Pt90/W10 wire better than pure platinum for medical electrodes?
    The 10% tungsten boosts strength and wear resistance while maintaining platinum’s conductivity and biocompatibility.

Related recommendations

×
Quote

Get a Quote

We provide the highest quality service

×